It’s 14°F outside, your heat pump has been running for two hours, and your thermostat just lit up with “AUX HEAT.” Before you call anyone — here’s what that actually means.
In most cases, you can relax. Auxiliary heat switching on during a cold snap is normal behavior, not a malfunction. (Most thermostats display this as “AUX HEAT” or “AUX” — Ecobee, Nest, and Honeywell each use slightly different labels, but the function is identical.) But “most cases” isn’t “always” — knowing the difference between expected operation and something worth investigating could save you a service call.
This guide covers what heat pump auxiliary heat is, when it’s normal versus a problem, how it differs from emergency heat, typical temperature thresholds, running costs, and clear signs it’s time to call a technician. For the full picture on heat pump types, costs, and whether one makes sense for your home, the heat pumps for homeowners guide covers it all — this article focuses specifically on auxiliary heat behavior.
This page contains affiliate links and may include sponsored content. As an Amazon Associate, I earn from qualifying purchases at no extra cost to you. Amazon links are labeled #ad; other affiliate links may be marked as “(paid link).” Affiliate Disclosure.
Table of Contents
- What Is Auxiliary Heat on a Heat Pump?
- Auxiliary Heat vs. Emergency Heat: These Are Not the Same Thing
- At What Temperature Does Auxiliary Heat Kick In?
- What Is the Heat Pump Defrost Cycle — and Why Does It Look Alarming?
- What Does Heat Pump Auxiliary Heat Cost to Run?
- Is My Heat Pump Auxiliary Heat Running Too Much?
- When Auxiliary Heat Is Actually a Problem
- What to Tell a Technician If You Call
- Frequently Asked Questions
- How to Reduce Auxiliary Heat Usage
- Conclusion
What Is Auxiliary Heat on a Heat Pump?
Understanding heat pump auxiliary heat starts with understanding what a heat pump does. It moves heat from the outdoor air into your home; it doesn’t generate heat by burning fuel, it transfers it. That process is highly efficient when outdoor temperatures are moderate, but as it gets colder outside, there’s less heat energy in the air to transfer, and the heat pump has to work harder to maintain the same output.
At some point — typically somewhere between 25°F and 40°F depending on the system — the heat pump alone can’t keep up with demand. Your thermostat senses that the indoor temperature is falling or struggling to rise, and it switches on auxiliary heat to close the gap.
Auxiliary heat is electric resistance heating: essentially the same technology as a baseboard heater or a toaster coil, just integrated into your air handler. It produces heat reliably regardless of outdoor temperature, but it’s significantly less efficient than the heat pump itself. According to the U.S. Department of Energy, heat pumps deliver two to four times more heat energy per unit of electricity than resistance heating — which is exactly why aux heat costs more per hour to run. Crucially, it runs alongside the heat pump rather than replacing it — the heat pump keeps running, and the aux strips add the extra heat on top.
Auxiliary Heat vs. Emergency Heat: These Are Not the Same Thing
This is the most common source of confusion, and most articles gloss over it. Auxiliary heat and emergency heat use the same physical components (the electric resistance strips), but they operate completely differently, and mixing them up can cost you real money.
| Mode | What it does | Who controls it | Heat pump running? |
|---|---|---|---|
| Auxiliary heat | Adds supplemental electric resistance heat when the heat pump can’t keep up alone | Thermostat — automatic | Yes — heat pump and aux run together |
| Emergency heat | Bypasses the heat pump entirely and runs pure electric resistance heat | You — manual switch on thermostat | No — heat pump is completely off |
When your thermostat displays “AUX HEAT,” that’s automatic and expected in cold weather. The system decided to add supplemental heat, and the heat pump is still your primary source.
When your thermostat displays “EM HEAT” or “EMERGENCY HEAT,” someone — probably you — manually switched to emergency heat mode. In this mode, the heat pump is completely shut off and you’re running pure resistance heat. It costs roughly two to three times as much to operate, and you should only use it if the heat pump itself is genuinely broken or a technician has told you to use it during service.
At What Temperature Does Auxiliary Heat Kick In?
The temperature at which heat pump auxiliary heat kicks in varies by system type — mostly whether you have a standard or cold-climate model. The technical term for the outdoor temperature where your heat pump’s output exactly matches your home’s heating demand is the balance point. Below that temperature, aux heat supplements the load to make up the difference.
| Outdoor temp | System behavior | Aux heat running? | Action |
|---|---|---|---|
| Above 40°F | Heat pump handles it alone | No — investigate if yes | Call tech if aux runs regularly at this temp |
| 30°F–40°F | Heat pump primary, may get some help | Occasionally normal | Watch your bill; normal if brief |
| 20°F–30°F | Heat pump struggling; aux kicks in regularly | Yes — normal | No action needed |
| 10°F–20°F | Aux heat running often; defrost cycles more frequent | Yes — normal and expected | No action; monitor for ice that won’t clear |
| Below 10°F | Standard systems lean heavily on aux; cold-climate models still performing | Yes — expected for standard systems | Normal unless home can’t reach set temp |
| Below 0°F | Standard systems near their limit; aux carrying most load | Heavy use — expected | If you can’t maintain 65°F, system may be undersized |
System-type balance points: standard models engage aux around 35°F–40°F; mid-range units around 25°F–35°F. For a heat pump in extreme cold — below 10°F — cold-climate models (Mitsubishi H2i, Bosch IDS, Daikin Fit) maintain output down to 5°F or -13°F with far less aux reliance.
The threshold also shifts based on how well-insulated your home is, whether your ducts leak, the system’s size relative to your heating load, and how large a temperature gap there is between the outdoor reading and your thermostat setting.
If you’re asking about heat pump performance in extreme cold weather, the honest answer depends heavily on whether you have a standard or cold-climate model. One important caveat: if you have a dual-fuel system — a heat pump paired with a gas furnace — your “aux heat” source is the furnace, not electric resistance strips. In that case, the cost and efficiency math is entirely different (gas is typically cheaper per BTU than electric resistance in most of the US). The thresholds above apply to all-electric systems with resistance strips as backup.
In a typical cold-climate home in Pennsylvania or Ohio, a heat pump running in extreme cold conditions — below 25°F–30°F — will display AUX HEAT regularly. (These thresholds are generalizations; your system’s actual balance point depends on your home’s insulation, duct condition, and how well the system was sized at install.) That’s normal operation, not a malfunction. If aux is coming on regularly when it’s 45°F outside, that’s a different conversation.
What Is the Heat Pump Defrost Cycle — and Why Does It Look Alarming?
The heat pump defrost cycle is one of the most misunderstood parts of normal system operation. You step outside on a cold morning and see steam — or what looks like smoke — rising from your outdoor unit. Your first instinct is probably wrong: it’s not burning, it’s defrosting.
On cold, humid days, frost can accumulate on the outdoor coil of your heat pump. If enough builds up, it blocks airflow and seriously hurts efficiency. So the system has a built-in defrost cycle that periodically reverses its operation to melt the frost off the coils. During the defrost cycle:
- The outdoor unit temporarily reverses and runs in cooling mode (even though it’s cold outside)
- The auxiliary heat strips turn on to keep warm air flowing through your house while the outdoor unit defrosts
- Steam or vapor rises from the outdoor unit — this is the frost melting, not smoke
- The cycle typically lasts 5 to 15 minutes
A normal heat pump defrost cycle runs every 30 to 90 minutes in cold, humid conditions and completes within 15 minutes. In practice, most homeowners barely notice it once they know what to expect: the indoor airflow continues, the house stays warm, and the unit clears itself. If your outdoor unit seems to be running a constant defrost cycle, defrosting for 30+ minutes at a stretch, or accumulating heavy ice that doesn’t clear, those are signs worth investigating.
Signs the defrost cycle may be a problem:
- Ice builds up on the outdoor unit and doesn’t clear within 15–20 minutes of defrost starting
- The bottom of the unit is blocked by a solid sheet of ice, not just light frost
- Defrost cycles seem to run constantly rather than periodically
- You’re losing noticeable heat output indoors during defrost
- The unit sounds different during defrost than it used to
If any of these apply, it could indicate a refrigerant issue, a dirty coil, a malfunctioning defrost board, or a blocked drain.
What Does Heat Pump Auxiliary Heat Cost to Run?
This is where the financial reality check lives. Auxiliary heat is electric resistance heating, which converts 1 kWh of electricity directly into 1 unit of heat (a COP, or coefficient of performance, of 1.0). Your heat pump in moderate conditions runs at a COP of 2.5 to 4.0, meaning it delivers 2.5 to 4 units of heat per unit of electricity consumed.
When heat pump auxiliary heat kicks in, you’re running resistance strips at COP 1.0 alongside whatever the heat pump is contributing. Total system efficiency drops. Here’s what that means in real dollars at common electric rates:
| Aux heat capacity | At 12¢/kWh | At 18¢/kWh | At 24¢/kWh |
|---|---|---|---|
| 5 kW (small system) | $0.60/hr | $0.90/hr | $1.20/hr |
| 10 kW (typical) | $1.20/hr | $1.80/hr | $2.40/hr |
| 15 kW (larger home) | $1.80/hr | $2.70/hr | $3.60/hr |
In homeowner forums, the pattern behind January bill spikes is almost always the same: aux heat running 4–6 hours a night, not 30 minutes. Running a heat pump in extreme cold weather is inherently more expensive than moderate-temperature operation, but it shouldn’t feel like a runaway cost. A 10 kW system running aux heavily at 18¢/kWh can add $25–$40 per night. Brief use on the coldest nights is expected; running constantly in mild weather is not.
Is My Heat Pump Auxiliary Heat Running Too Much?
Enter your outdoor temp and how long aux heat has been running.
If the checker flags your situation as worth watching or worth a call, the next section covers the specific warning signs that technicians look for.
When Auxiliary Heat Is Actually a Problem
Aux heat running occasionally in cold weather is expected. These situations are not:
Aux heat runs when it’s above 40°F outside
Unless your thermostat is set unusually high or you just made a large temperature adjustment, aux heat shouldn’t be needed when it’s 45°F outside. The honest answer is: the exact threshold varies enough by system that it’s hard to draw a hard line — but trust your instincts if it feels like it’s running more than it used to for the same weather conditions. If it’s running regularly in mild weather, the heat pump may be undersized, have a refrigerant leak, or have a failing compressor.
Aux heat runs continuously for hours without stopping
Aux heat is designed to supplement, not carry the full heating load. If it’s been running solidly for 4–6+ hours and your home still isn’t reaching the set temperature, something is wrong: either with the heat pump itself or with a much larger heat loss issue in the house.
Your bill suddenly jumps without a weather explanation
If your electric bill is more than 30–40% higher than the same month last year — with comparable weather — and you’re seeing aux heat run frequently, that’s worth investigating. A refrigerant charge issue, a failing reversing valve, or a stuck defrost board can all cause the aux strips to compensate for a heat pump that isn’t performing correctly.
You see “EM HEAT” and didn’t turn it on
Emergency heat should only activate if you manually select it. If it’s displaying on its own, call your HVAC technician.
Ice that won’t clear from the outdoor unit
A thin layer of frost on the outdoor coil is normal in cold, humid conditions. A solid block of ice that doesn’t clear after a defrost cycle is not normal, and it can permanently damage the unit if left unaddressed.
What to Tell a Technician If You Call
HVAC technicians bill by the hour. Walking in with specific information typically turns a 90-minute diagnostic visit into a 30-minute one. Note down:
- The outdoor temperature when aux heat seems to run more than expected
- Whether you’re seeing “AUX HEAT” or “EM HEAT” on the thermostat
- How long aux heat runs continuously before cycling off
- Whether the outdoor unit has visible ice buildup and whether defrost cycles seem to clear it
- Any change in heating output — rooms that used to get warm that now stay cold
- Your electric bill compared to the same period last year
This gives the technician enough to make a diagnosis without charging you an hour of diagnostic time to establish basics.
Frequently Asked Questions
How to Reduce Auxiliary Heat Usage
If aux heat is running more than you’d like — or your bill is higher than expected — these changes can reduce how often it activates without sacrificing comfort:
- Raise the thermostat gradually. A jump of 3°F+ at once triggers aux heat even in mild weather. Raise 1–2 degrees at a time and the heat pump handles it without the strips.
- Improve insulation and seal air leaks. The better your home holds heat, the longer the heat pump stays within its efficient range before aux kicks in. Attic insulation and door/window sealing are the highest-ROI fixes.
- Keep the outdoor unit clear. Snow packed against the unit or debris blocking airflow hurts efficiency and forces earlier aux engagement. A quick check after heavy snowfall is worth it.
- Use your thermostat’s aux lockout setting. Many thermostats (including Nest, Ecobee, and Honeywell) let you set a minimum outdoor temperature below which aux is allowed to run. If yours never locks out, it may be engaging earlier than necessary.
- Consider a cold-climate upgrade. If you have a standard heat pump and heavy aux heat use is a consistent winter problem, a cold-climate model (Mitsubishi H2i, Bosch IDS, Daikin Fit) maintains much higher efficiency at low temperatures — often running little to no aux heat down to 5°F.
Conclusion
Seeing “AUX HEAT” on your thermostat during a cold snap is normal — your heat pump auxiliary heat is doing exactly what it’s built to do. The key is knowing when that behavior crosses from expected operation into something worth investigating. If aux heat runs in mild weather, runs non-stop without your home warming up, or you’re seeing emergency heat you didn’t turn on yourself, those are the signals that warrant a call. Everything else: check the outdoor temp, give it time, and watch the bill.
Ask a Licensed HVAC Technician
Not sure if your aux heat behavior warrants a service call? JustAnswer connects you with a licensed HVAC technician who can assess your system — outdoor temps, duration, thermostat readings, any unusual sounds — and tell you whether it’s normal operation or worth an in-person diagnostic visit.
This article is for general informational purposes. Heat pump behavior varies by model, installation quality, and home characteristics. If you’re unsure whether your system is operating correctly, a diagnostic visit from a licensed HVAC technician is the most reliable answer. Acara Institute is not affiliated with any HVAC installer, manufacturer, or service provider.